Technical Support Note
======================
Product(s) involve : Sound Blaster 16 MCD
: Sound Blaster Pro Mitsumi Interface
: Sound Blaster 16 Mitsumi Interface
Third party product(s) : Mitsumi CD Audio Cable
Subject
-------
No CD audio output after connecting the Mitsumi drive using the CD audio cable
provided by Mitsumi.
Description
-----------
User will encounter the above-mentioned problem when connecting their
Mitsumi CDROM drive (CD Audio output) using the cable supplied by Mitsumi to
the "CD_IN" connector of the SB16MCD, SBP Mitsumi and SB16 Mitsumi. The
reason is that the CD audio PIN signals on the Mitsumi drive are different from
that of the SB16MCD, SBP Mitsumi and SB16 Mitsumi "CD_IN" connector.
Solution/Action
---------------
As the solution requires rewiring of the cables, user who encountered this
problem are encouraged to purchase the CD audio cable from Creative.
Alternatively, user who prefer to rewire the cables can refer to the following pin-
out diagram:
Mitsumi Drive Pin 1 2 3 4
Signal R G L G
SB "CD_IN" Pin 1 2 3 4
Signal G L G R
3rd January, 1994
Issue No: TSN94002
Technical Services Department, Creative Technology Ltd